Static Leach Analysis
Dynamic Leach Analysis
Surface Analysis

Email

Literature Request

Static Leach Analysis

Detailed extractable analysis is conducted on piping samples after seven-day static leach utilizing 18.2 megohm ultra-pure water at ambient temperature. Static leach of large pipe samples (120-square-inch wet surface area) is representative of a piping system “off-line” for an extended period of time. Under these conditions the effects of UPW can be extremely aggressive, severely affecting the amount of leachable contaminants present within the piping material.

Pipe Material
Element DL
(Detection Limit)
ppb
Harvel
LXT®
High
Purity
PVDF
High
Purity
PP
Brand X
Clean
PVC
Conv.
PVC
CPVC
TOC 5 59 90 94 1176 * 50
Flouride 2 * 77 * * * *
Chloride 0.25 2.33 1.0 0.66 2.45 0.84 49.54
Aluminum 0.05 0.30 2.3 0.68 0.54 3.10 1.16
Barium 0.01 0.04 0.24 0.09 0.01 0.22 0.05
Calcium 3 7 * 12 206 2787 15
Magnesium 0.02 0.81 0.66 1.0 2.15 11.15 2.17
Sodium 0.06 0.83 0.51 0.18 0.49 1.23 23.22
Tin 0.02 0.93 * * 0.15 0.51 1.19
Zinc 0.06 0.49 0.47 0.96 * 0.51 1.19

* = Below Detection Limit
 
• All samples pre-rinsed identically with UPW prior to test.
• Independent Laboratory Extractable Analysis
(Balazs Analytical Laboratory)
• Seven-Day Static Leach @ ambient temperature
• 450mL 18.2 megohm ultra-pure water
• 120-square-inch wet surface contact area
• Based on 1" diameter pipe without solvent-cemented joint
• Concentration units expressed as ug/L of Leachate (ppb)

Contact Harvel for additional detailed reports.